Vanguard Pharmaceutical Machinery Autoclaves

Autoclaves Machine

Introduction
TMQ.J & TMQ.R
TMQ.C & LMQ.R

 

Espanol

Vanguard Pharmaceutical Machinery Autoclaves, Quick Sterilzing Eqipment

 Model

 TMQ.C - 2540

 TMQ.C - 3250
 Working Capacity 23 L 45 L
 Working Area (mm) 250 x 440 315 x 575
 Dimension (mm) 655 x 510 x 375 790 x 575 x 420
 Tray Size (mm) 440 x 195 520 x 260
520 x 300
 Power 110V   2.2kW 110V  2.85kW
    Main Features
  • PC Control and touch switches are adopted.
  • Temperature and time are displayed dynamically and digitally.
  • A failure display system is equipped.
  • A signal will be given off by speaker when the procedure is finished.
  • 4 sterilizing programs are available.
  • Printer can be equipped as an option.
  • The safety of the equipment is guaranteed by an over heating auto protection device.
  • The safety of operation is guaranteed by the quick opening pressure safe chain device.
  • The safety is guaranteed by a safety valve that can decrease the pressure when it is too high.
  • Environment is kept clean and dry because there are inner cycle systems for water and gas, and it does not need an outer water source.
  • AID virus and hepatitis virus can be killed.
Vanguard Pharmaceutical Machinery Autoclaves TMQ.C



 Model

 LMQ.R - 3260A

 LMQ.R - 4060
 Working Capacity 48 L 75 L
 Working Area (mm) 315 x 590 400 x 600
 Dimension (mm) 570 x 420 x 830 766 x 524 x 900
 Tray Size (mm) 306 x 240 380 x 200
306 x 260 380 x 260
 Power 110V   3.6kW 110V  6kW
    Main Features
  • The process of water infusion, heating, sterilization, gas exhaust, and drying is auto controlled by program.
  • Temperature and time are displayed dynamically and digitally.
  • A failure display system is equipped.
  • A signal will be given off by speaker when the procedure is finished.
  • The safety of the equipment is guaranteed by an over heating auto protection device.
  • The safety of operation is guaranteed by the quick opening pressure safe chain device.
  • The safety is guaranteed by a safety valve that can decrease the pressure when it is too high.
  • Environment is kept clean and dry because there are inner cycle systems for water and gas, and it does not need outer water source.
  • AID virus and hepatitis virus can be killed.
Vanguard Pharmaceutical Machinery Autoclaves LMQ.R